TCX® (I) 150/250 (300) V
TCX (I) 150/250V 1P0.5
Nexans ref. 10169719 - Country ref. 1042146
- Packaging: Cut to length (m)
- Number of pairs: 1
- Conductor cross-section: 0.5 mm²
- Minimum outer diameter: 6.2 mm
- Maximum outer diameter: 7.4 mm
- Approximate weight: 60 kg/km
TCX (I) 150/250V 2P0.5
Nexans ref. 10189175 - Country ref. 1042147
- Packaging: Cut to length (m)
- Number of pairs: 2
- Conductor cross-section: 0.5 mm²
- Minimum outer diameter: 8.8 mm
- Maximum outer diameter: 10.5 mm
- Approximate weight: 130 kg/km
TCX (I) 150/250V 4P0.5
Nexans ref. 10189176 - Country ref. 1042148
- Packaging: Cut to length (m)
- Number of pairs: 4
- Conductor cross-section: 0.5 mm²
- Minimum outer diameter: 10.5 mm
- Maximum outer diameter: 12.5 mm
- Approximate weight: 162 kg/km
TCX (I) 150/250V 7P0.5
Nexans ref. 10189177 - Country ref. 1042149
- Packaging: Cut to length (m)
- Number of pairs: 7
- Conductor cross-section: 0.5 mm²
- Minimum outer diameter: 12.0 mm
- Maximum outer diameter: 14.0 mm
- Approximate weight: 254 kg/km
TCX (I) 150/250V 10P0.5
Nexans ref. 10211616 - Country ref. 1042150
- Packaging: Cut to length (m)
- Number of pairs: 10
- Conductor cross-section: 0.5 mm²
- Minimum outer diameter: 14.5 mm
- Maximum outer diameter: 16.5 mm
- Approximate weight: 360 kg/km
TCX (I) 150/250V 1P0.75
Nexans ref. 10170057 - Country ref. 1042151
- Packaging: Cut to length (m)
- Number of pairs: 1
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 7.0 mm
- Maximum outer diameter: 8.2 mm
- Approximate weight: 80 kg/km
TCX (I) 150/250V 2P0.75
Nexans ref. 10170061 - Country ref. 1042152
- Packaging: Cut to length (m)
- Number of pairs: 2
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 10.0 mm
- Maximum outer diameter: 12.0 mm
- Approximate weight: 153 kg/km
TCX (I) 150/250V 4P0.75
Nexans ref. 10170094 - Country ref. 1042153
- Packaging: Cut to length (m)
- Number of pairs: 4
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 12.0 mm
- Maximum outer diameter: 14.0 mm
- Approximate weight: 216 kg/km
TCX (I) 150/250V 7P0.75
Nexans ref. 10170097 - Country ref. 1042154
- Packaging: Cut to length (m)
- Number of pairs: 7
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 14.5 mm
- Maximum outer diameter: 17.0 mm
- Approximate weight: 353 kg/km
TCX (I) 150/250V 10P0.75
Nexans ref. 10170099 - Country ref. 1042155
- Packaging: Cut to length (m)
- Number of pairs: 10
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 17.5 mm
- Maximum outer diameter: 20.0 mm
- Approximate weight: 473 kg/km
TCX (I) 150/250V 14P0.75
Nexans ref. 10170102 - Country ref. 1042156
- Packaging: Cut to length (m)
- Number of pairs: 14
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 19.5 mm
- Maximum outer diameter: 22.0 mm
- Approximate weight: 610 kg/km
TCX (I) 150/250V 19P0.75
Nexans ref. 10183965 - Country ref. 1042157
- Packaging: Cut to length (m)
- Number of pairs: 19
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 21.5 mm
- Maximum outer diameter: 24.5 mm
- Approximate weight: 768 kg/km
TCX (I) 150/250V 24P0.75
Nexans ref. 10191222 - Country ref. 1042158
- Packaging: Cut to length (m)
- Number of pairs: 24
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 24.0 mm
- Maximum outer diameter: 27.0 mm
- Approximate weight: 926 kg/km
TCX (I) 150/250V 1P1.5
Nexans ref. - Country ref. 1042159
- Packaging: Cut to length (m)
- Number of pairs: 1
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 8.2 mm
- Maximum outer diameter: 9.6 mm
- Approximate weight: 110 kg/km
TCX (I) 150/250V 2P1.5
Nexans ref. 10170127 - Country ref. 1042160
- Packaging: Cut to length (m)
- Number of pairs: 2
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 12.5 mm
- Maximum outer diameter: 14.5 mm
- Approximate weight: 260 kg/km
Description
Description
Standards
-
InstallationIEC 60092-350; IEC 60092-360; IEC 60092-376
-
TestIEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
TCX® (I) 150/250 V armoured individually screened twisted pair cables are used for telecommunication and instrumentation purposes. These cables provide strong protection aganist cross-talk in both low and high frequency runs, making them suitable for highly polluted electromagnetic surroundings. TCX®(I) cables are also selected where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
Design
- Conductor:
Stranded bare copper class 2
- Insulation:
XLPE (cross-linked polyethylene)
- Individual screen:
Alu/polyester tape with a tinned copper drain wire
- Assembling:
Polyester tape
- Armour:
Bare copper braid
- Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour : grey
Marking
NEXANS 279 TCX (I) Nber of pairs/triads & cross section 150/250V 90C IEC 60092-376 IEC 60332-3-22 Cat. A WW YYYY *CE* Manufacturing n° + metric marking
Core identification
Pair: white / blue with printed pair number
Triad: white / blue / red with printed triad number
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania