TCX® (I) 150/250 (300) V

Products

TCX (I) 150/250V 1P0.5

Nexans ref. 10169719 - Country ref. 1042146

  • Packaging: Cut to length (m)
  • Number of pairs: 1
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 6.2 mm
  • Maximum outer diameter: 7.4 mm
  • Approximate weight: 60 kg/km

 

TCX (I) 150/250V 2P0.5

Nexans ref. 10189175 - Country ref. 1042147

  • Packaging: Cut to length (m)
  • Number of pairs: 2
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 8.8 mm
  • Maximum outer diameter: 10.5 mm
  • Approximate weight: 130 kg/km

 

TCX (I) 150/250V 4P0.5

Nexans ref. 10189176 - Country ref. 1042148

  • Packaging: Cut to length (m)
  • Number of pairs: 4
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 10.5 mm
  • Maximum outer diameter: 12.5 mm
  • Approximate weight: 162 kg/km

 

TCX (I) 150/250V 7P0.5

Nexans ref. 10189177 - Country ref. 1042149

  • Packaging: Cut to length (m)
  • Number of pairs: 7
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 12.0 mm
  • Maximum outer diameter: 14.0 mm
  • Approximate weight: 254 kg/km

 

TCX (I) 150/250V 10P0.5

Nexans ref. 10211616 - Country ref. 1042150

  • Packaging: Cut to length (m)
  • Number of pairs: 10
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 14.5 mm
  • Maximum outer diameter: 16.5 mm
  • Approximate weight: 360 kg/km

 

TCX (I) 150/250V 1P0.75

Nexans ref. 10170057 - Country ref. 1042151

  • Packaging: Cut to length (m)
  • Number of pairs: 1
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 7.0 mm
  • Maximum outer diameter: 8.2 mm
  • Approximate weight: 80 kg/km

 

TCX (I) 150/250V 2P0.75

Nexans ref. 10170061 - Country ref. 1042152

  • Packaging: Cut to length (m)
  • Number of pairs: 2
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 10.0 mm
  • Maximum outer diameter: 12.0 mm
  • Approximate weight: 153 kg/km

 

TCX (I) 150/250V 4P0.75

Nexans ref. 10170094 - Country ref. 1042153

  • Packaging: Cut to length (m)
  • Number of pairs: 4
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 12.0 mm
  • Maximum outer diameter: 14.0 mm
  • Approximate weight: 216 kg/km

 

TCX (I) 150/250V 7P0.75

Nexans ref. 10170097 - Country ref. 1042154

  • Packaging: Cut to length (m)
  • Number of pairs: 7
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 14.5 mm
  • Maximum outer diameter: 17.0 mm
  • Approximate weight: 353 kg/km

 

TCX (I) 150/250V 10P0.75

Nexans ref. 10170099 - Country ref. 1042155

  • Packaging: Cut to length (m)
  • Number of pairs: 10
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 17.5 mm
  • Maximum outer diameter: 20.0 mm
  • Approximate weight: 473 kg/km

 

TCX (I) 150/250V 14P0.75

Nexans ref. 10170102 - Country ref. 1042156

  • Packaging: Cut to length (m)
  • Number of pairs: 14
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 19.5 mm
  • Maximum outer diameter: 22.0 mm
  • Approximate weight: 610 kg/km

 

TCX (I) 150/250V 19P0.75

Nexans ref. 10183965 - Country ref. 1042157

  • Packaging: Cut to length (m)
  • Number of pairs: 19
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 21.5 mm
  • Maximum outer diameter: 24.5 mm
  • Approximate weight: 768 kg/km

 

TCX (I) 150/250V 24P0.75

Nexans ref. 10191222 - Country ref. 1042158

  • Packaging: Cut to length (m)
  • Number of pairs: 24
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 24.0 mm
  • Maximum outer diameter: 27.0 mm
  • Approximate weight: 926 kg/km

 

TCX (I) 150/250V 1P1.5

Nexans ref. - Country ref. 1042159

  • Packaging: Cut to length (m)
  • Number of pairs: 1
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 8.2 mm
  • Maximum outer diameter: 9.6 mm
  • Approximate weight: 110 kg/km

 

TCX (I) 150/250V 2P1.5

Nexans ref. 10170127 - Country ref. 1042160

  • Packaging: Cut to length (m)
  • Number of pairs: 2
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 12.5 mm
  • Maximum outer diameter: 14.5 mm
  • Approximate weight: 260 kg/km

 

Description

Description

Standards

  • Installation
    IEC 60092-350; IEC 60092-360; IEC 60092-376
  • Test
    IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

TCX® (I) 150/250 V armoured individually screened twisted pair cables are used for telecommunication and instrumentation purposes. These cables provide strong protection aganist cross-talk in both low and high frequency runs, making them suitable for highly polluted electromagnetic surroundings. TCX®(I) cables are also selected where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

 

Design

  1. Conductor:
    Stranded bare copper class 2
     
  2. Insulation:
    XLPE (cross-linked polyethylene)
     
  3. Individual screen:
    Alu/polyester tape with a tinned copper drain wire
     
  4. Assembling:
    Polyester tape
     
  5. Armour:
    Bare copper braid
     
  6. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour : grey 
     

Marking

NEXANS 279 TCX (I) Nber of pairs/triads & cross section 150/250V 90C IEC 60092-376 IEC 60332-3-22 Cat. A WW YYYY *CE* Manufacturing n° + metric marking

 

Core identification

Pair: white / blue with printed pair number
Triad: white / blue / red with printed triad number

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Conductor material
Bare copper
Insulation
XLPE (Cross-linked Polyethylene)
Individual screen
Tinned copper drain wire + aluminium/polyester tape
Inner covering
Polyester tape(s)
Armour type
Bare copper braid
Outer sheath
Polyolefin
Sheath colour
Grey

Dimensional characteristics

Dimensional characteristics

Number of triples
-

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Flame retardant
IEC 60332-1
Gases corrosivity
IEC 60754-2
Smoke density
IEC 61034
Electro magnetic interference resistance
Yes
Operating temperature, range
-30 ... 80 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close